Hydroflo Pumps
At Process & Power, we proudly supply Hydroflo Pumps, a U.S.-based manufacturer specializing in vertical and submersible turbine pumps. Founded in 1998 and headquartered in Tennessee, Hydroflo has built a strong reputation for engineering reliable, efficient pumping solutions for agriculture, industrial facilities, municipal water systems, and power generation applications.
Product Highlights
Vertical Turbine Pumps – Rugged designs for deep well, irrigation, and municipal water supply.
Submersible Turbine Pumps – Compact, efficient options for groundwater and high-capacity pumping.
Mixed Flow Pumps – Built for large-volume, low-head applications such as flood control and cooling systems.
Axial Flow Pumps – Ideal for drainage, circulation, and flood management where high volume is critical.
Custom Engineered Systems – Tailored pumping packages designed for unique industrial and municipal projects.
Why Choose Hydroflo?
American-made pumps with engineering and manufacturing based in Tennessee
Proven reliability across agricultural, municipal, industrial, and power markets
Customizable solutions designed to meet exact customer requirements
Contact Process & Power for Hydroflo Pumps
Located at: 1721 Corporate Avenue • Memphis, TN 38132
Call us at: (901) 362-5500
Contact Us
Hydroflo Pumps FAQ
What Hydroflo pump types are featured?
The page focuses on vertical and submersible turbine equipment, along with engineered options for agricultural, municipal, and industrial water movement.
Can Hydroflo equipment be considered for groundwater supply?
Yes, where the selected assembly suits the well and required duty. Provide well yield, water levels, dimensions, and water quality.
How does a surface driver affect the installation?
A lineshaft arrangement requires suitable mounting, alignment, and access above the pump. Confirm driver loads and service clearances along with hydraulic performance.
What should be reviewed for a high-volume water application?
Define the required flow and head, intake geometry, water levels, and discharge arrangement. Flood-control and circulation duties can differ substantially from well-supply duties.
Can a pump be selected for changing seasonal demand?
Yes, but the full range should be evaluated. Check operating limits, available water supply, and any proposed variable-speed control across that range.
What drawings help when replacing a vertical pump?
Provide the mounting layout, column and bowl details, discharge connections, and setting depth. Document the driver and any installation constraints.
What measurements are needed to size a turbine pump?
Provide flow, total head, pumping water level, well or sump dimensions, and available power. Include seasonal drawdown and discharge losses so selection reflects the actual operating conditions.
How is a vertical turbine pump different from a submersible turbine pump?
A typical vertical lineshaft installation has its driver above the liquid, while a submersible arrangement places the motor below. Installation geometry, access, and operating conditions influence the choice.
Why has the pump lost pressure or capacity?
Changing water levels, wear, restrictions, incorrect speed, or air entering the intake can reduce performance. Compare current measurements with commissioning data and the pump curve.
Why is my vertical pump vibrating?
Potential causes include alignment, shaft or bearing wear, structural resonance, and poor intake conditions. Evaluation should consider the complete assembly and its operating speed range.
Why does intake submergence matter?
Insufficient liquid depth above the intake can encourage vortices and air entry. Required submergence depends on the pump, flow, and intake geometry and should be checked during selection.
Can these pumps run dry?
Do not assume dry operation is permitted. The bowls, bearings, and motor cooling arrangement may depend on water; review the model's lubrication and minimum-level requirements.
What should a turbine-pump maintenance plan include?
Follow the specific assembly's instructions for bearings, lubrication, seals or packing, and drive alignment. Trend water levels, flow, pressure, current, and vibration to identify changes.
Can an existing turbine pump be rebuilt or upgraded?
Evaluate the bowls, shafting, column, bearings, and driver alongside current duty requirements. Available parts and removal costs help determine whether rebuilding or replacement is practical.
How can I get local support for Hydroflo Pumps?
Contact Process & Power at (901) 362-5500 with your location, equipment identification, and application or service concern. The team can review selection, parts, and service options for your needs.
What should I send when requesting a quote?
Include the required duty, fluid or process details, operating conditions, utilities, and installation dimensions. For existing equipment, add nameplate photos, model and serial numbers, and a description of the problem or planned change.