Rotech Pumps
Process & Power is proud to offer Rotech Pumps, a U.S.-based manufacturer known for designing and engineering reliable ANSI and API centrifugal pumps. With a commitment to quality and cost-effective performance, Rotech Pumps are built to meet the demanding needs of industrial, chemical, petrochemical, and municipal applications.
Product Highlights
ANSI Process Pumps – Interchangeable with major OEM brands, designed for chemical, industrial, and general process applications.
API Process Pumps – Engineered to meet stringent API standards for oil & gas and petrochemical industries.
Mag-Drive Pumps – Sealless designs for leak-free operation when handling corrosive or hazardous liquids.
Horizontal Split Case Pumps – Efficient solutions for high-capacity water movement and cooling applications.
Spare Parts & Interchangeability – High-quality aftermarket parts compatible with other OEM pump lines.
Why Choose Rotech?
ANSI and API compliant designs for industrial reliability
Cost-effective alternatives with full interchangeability to OEM parts
Strong reputation for durability, serviceability, and value
Contact Process & Power for Rotech Pumps
Located at: 1721 Corporate Avenue • Memphis, TN 38132
Call us at: (901) 362-5500
Contact Us
Rotech Pumps FAQ
What Rotech equipment is featured?
The page presents process-pump, magnetic-drive, split-case, and replacement-part options. Confirm the current model and configuration against the required application.
How do ANSI and API pump requirements differ?
They address different equipment and service requirements. Identify the project specification and applicable edition, then verify the offered pump's documented compliance rather than assuming the terms are interchangeable.
Can Rotech equipment replace an existing process pump?
Potential replacements require comparison of the duty, materials, dimensions, driver, and connections. Confirm any claimed parts or dimensional interchangeability for the exact models involved.
When is a split-case arrangement worth considering?
It may suit water movement where capacity and service access are priorities. Compare the pump curve, installation footprint, and maintenance access with other designs.
What is the purpose of a magnetic drive?
It transmits torque without a conventional dynamic shaft seal through the containment boundary. Static joints and other components still need inspection and compatible materials.
What should I provide when ordering Rotech parts?
Supply the model, serial number, part identification, and service conditions. Photos or drawings can help confirm the correct material and revision.
How do I choose the right pump size?
Start with required flow and total head, then check the operating point against the pump curve. Horsepower or pipe size alone is not enough to select a pump.
Why is my pump running but delivering less flow?
Possible causes include suction restrictions, air entry, worn hydraulic components, incorrect rotation, or changed system resistance. Compare measured flow and pressures with the expected operating point.
What is cavitation, and why does it matter?
Cavitation occurs when local pressure falls low enough for vapor bubbles to form and then collapse. Review suction conditions, liquid temperature, and available inlet head when noise or performance changes appear.
What can cause excessive pump vibration?
Alignment, bearings, impeller condition, mounting, piping strain, and hydraulic conditions can all contribute. Record when vibration occurs so inspection can address the cause rather than just the symptom.
Why might a pump seal start leaking?
Dry running, unsuitable seal materials, poor flush conditions, shaft movement, or normal wear can cause leakage. Repeated failures warrant a review of the operating conditions and seal arrangement.
How often should this pump receive maintenance?
Use the model's instructions and service history to set intervals. Track operating hours, leakage, vibration, lubrication requirements, and performance changes rather than relying on a universal calendar schedule.
Should I rebuild the pump or replace it?
Compare inspection findings, parts availability, repair cost, downtime, and current duty requirements. Rebuilding is worth evaluating when the casing and major components remain suitable for the application.
Can a variable-speed drive reduce pumping costs?
It may help when demand varies and the system allows speed adjustment. Check minimum flow, motor suitability, control needs, and measured energy use before estimating savings.
How can I get local support for Rotech Pumps?
Contact Process & Power at (901) 362-5500 with your location, equipment identification, and application or service concern. The team can review selection, parts, and service options for your needs.
What should I send when requesting a quote?
Include the required duty, fluid or process details, operating conditions, utilities, and installation dimensions. For existing equipment, add nameplate photos, model and serial numbers, and a description of the problem or planned change.